- Module Ultrasonic Flow meter
- Portable Ultrasonic Flow meter
- Handheld Ultrasonic Flow meter
- Handheld Ultrasonic Flowmeter
- Wall mounted clamp on Ultrasonic flow meter
Module Ultrasonic Flow meter
Use Medium: Liquid
With mounting bracket
Easy mounting
220VAC 50/60Hz powered
LCD display
Specifications
Transmitter
Power | 220V AC 50/60 Hz |
Velocity Range | 0-32m/s |
Output | RS485, heat, 4-20mA 2 wire |
Display | 2 line characters display instantaneous and accumulative flow, velocity and signal status |
Units | m3(/s/m/h/d), cubic feet, liter, gallon, etc. |
Ambient conditions | -20 °C to +75 °C, 0 to 85% relative humidity |
Size | 220*125*92mm, 800g |
Accuracy | Flow: ± 1% reading, Heat: ± 2%(at calibrated conditions) |
Repeatability | 0.20% |
Portable Ultrasonic Flow Meter
Use Medium: Liquid
Small in size
With Printer
2GB SD card
Battery powered
Specifications
Transmitter
Power requirements | Built-in 24V Ni-MH battery provides 24 hrs of continuous operation |
Charging | 220V AC 50/60 Hz |
Velocity range | 0-32m/s |
Output | RS485, heat |
Display | 2 line characters display instantaneous and accumulative flow, velocity and signal status |
Units | m3(/s/m/h/d), cubic feet, liter, gallon, etc. |
Ambient conditions | -20 °C to +75 °C, 0 to 85% relative humidity |
Size | 220*125*92mm, 800g |
Accuracy | Flow: ± 1% reading, Heat: ± 2%(at calibrated conditions) |
Repeatability | 0.20% |
Transducer
Type | S1 M1 L1 |
Applicable pipe (mm) | 10~6000 |
Material | PES (Polyether Sulfone) |
Working frequency | 1 MHZ |
Installation method | V, Z |
Calibration | Pairing & Calibrating for the complete machine |
Magnetism | no |
Applicable temperature | -40~160 °C |
Protection | IP68 |
Media type | Water, seawater, sewage, alcohol, various oils and other single, uniform and stable liquid that can transmit ultrasonic wave |
Medium turbidity | 20000ppm with low bubble content |
Applicable pipes | Uniform and compact pipes made of carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastics, and lining is permitted. |
Pipe lining material | Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, bakelite, polytetrafluoroethylene etc. |
Signal cable | Standard configuration: 5mX2, and 10mX2 or 15mX2 are optional. |
Heat Measurement
The portable ultrasonic flow meter with optional heat flow module installed is designed to measure the rate and quantity of heat delivered to a given building, area or heat exchanger. The meter measures the volumetric flow rate of the heat exchanger liquid (water, water/glycol mixture, brine, etc.), the high temperature at the inlet pipe and the low temperature at the outlet pipe. Heat delivery is calculated by the following equation.
Rate of heat delivery = Q*(Tin – Tout)*c
Where
Q = volumetric flow rate
Tin = high temperature at the inlet
Tout = low temperature at the outlet
C = specific heat of the liquid
Handheld Ultrasonic Flow meter
Use medium:Liquid
New design, new shape
Two Line LCD display
English, Italian and Chinese are available
Modbus/RS485 protocal
2GB storage card
Transmitter
Power requirements | Built-in 24V Ni-MH battery provides 24 hrs of continuous operation |
Charging | 220V AC 50/60 Hz |
Protocal | RS485 |
Display | 2 line characters display instantaneous and accumulative flow, velocity and signal status |
Units | m3(/s/m/h/d), cubic feet, liter, gallon, etc. |
Ambient conditions | -20 °C to +75 °C, 0 to 85% relative humidity |
Size | 220*120*92mm, 600g |
Flow rate | 0-32m/s |
Accuracy | 1~3% |
Repeatability | 0.20% |
Transducer
Type | S1 M1 L1 |
Applicable pipe (mm) | 15~100; 50~700; 300~6000 |
Material | Aluminum alloy |
Working frequency | 1 MHZ |
Installation method | V (N,W) |
Calibration | Pairing & Calibrating for the complete machine |
Magnetism | Yes |
Applicable temperature | -40~90 °C |
Protection | IP68 |
Media type | Water, seawater, sewage, alcohol, various oils and other single, uniform and stable liquid that can transmit ultrasonic wave |
Medium turbidity | <20000ppm with low bubble content |
Applicable pipes | Uniform and compact pipes made of carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastics, and lining is permitted. |
Pipe lining material | Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, bakelite, polytetrafluoroethylene etc. |
Signal cable | Standard configuration: 5mX2, and 10mX2 or 15mX2 are optional. |
Handheld Ultrasonic Flowmeter
Use medium:Liquid
Linearity: better than 0.5%
Repeatability: better than 0.2%
Accuracy: better than ±1%
Non-intrusive, clamp-on transducer
No pressure drop, no pipe disturbance
Items | Performance and Parameter | |
Main Unit | Principle | transit-time ultrasonic flowmeter |
Accuracy | Accuracy :over 1%-2%; Repeatability: over 0.2% | |
Display | 4 line x 16 character LCD with backlight | |
Dimension | 200*93*33cm: 390g | |
Operation | Support 16 key light touch keyboard and the Simulation keyboard software | |
Data interface | Insulate RS232 serial interface, upgrade the flew meter software by computer, support the MODBUS, etc. | |
Signal Output | 1 way OCT output | |
Special Cable | Twisted-pair cable, ;Select the RS232 communication.; Generally, the standard is 5m*2, optional 10m*2 | |
Pipe Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed. |
Pipe Diameter | DN 15---6000mm | |
Straight length pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump. | |
Measuring Medium | Type of Liquid | Water ; Ultra-pure liquids; Solvents and other liquids |
Temperature | Standard Transducer: -30--90℃; High-temperature transducer: -40--160℃ | |
Turbidity | under 10000ppm and less bubble | |
Flow rate | 0--±10m/s | |
Flow Direction | Measuring two (plus-minis) direction of flow rate | |
Working Environment | Temperature | Main Unit: -20--60℃ |
Flow transducer: -40--160℃; Temperature transducer: according to the customer’s demands. | ||
Straight length pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump. | |
Power Supply | AC 110V-240V |
Wall mounted clamp on Ultrasonic Flow Meter
Use medium:Liquid
Linearity: better than 0.5%
Repeatability: better than 0.2%
Accuracy: better than ±1%
Non-intrusive, clamp-on transducer
No pressure drop, no pipe disturbance
Items | Specifications |
Main unit | 2 line x 20 character LCD with backlight Working temperature: -25--60℃ Mini thermal printer with 24 line character output 4x4+2 pushbutton keypad RS-485 interface for networking |
Signal input & output | 1 channel 4-20mA output 1channel OCT output 1channel relay output 3 channel 4-20mA input |
Medium | Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, acids, etc.); Plant effluent; Beverage, liquid food; Ultra-pure liquids; Solvents and other liquids |
Flow rate Range | 0~±10m/s |
Accuracy | Better than ±1% |
Battery | Built-in rechargeable Ni-MH rechargeable battery, provide over 20 hours of continuous operation |
Power Consumption | 1.5W |
Power supply | Built-in rechargeable Ni-MH battery (for 20 hours operation) or AC 220V |
Weight & Dimensions | 2.5kg ; 225*180*67mm: |
Remarks | With a high strength carrying case suitable for normal and harsh environment |