+91 40 23549924/8905

info@lagasys.com

Ultrasonic Flowmeters


Module Ultrasonic Flow meter

Use Medium: Liquid

With mounting bracket

Easy mounting

220VAC 50/60Hz powered

LCD display

Specifications

Transmitter
Power 220V AC 50/60 Hz
Velocity Range 0-32m/s
Output RS485, heat, 4-20mA 2 wire
Display 2 line characters display instantaneous and accumulative flow, velocity and signal status
Units m3(/s/m/h/d), cubic feet, liter, gallon, etc.
Ambient conditions -20 °C to +75 °C, 0 to 85% relative humidity
Size 220*125*92mm, 800g
Accuracy Flow: ± 1% reading, Heat: ± 2%(at calibrated conditions)
Repeatability 0.20%

Portable Ultrasonic Flow Meter

Use Medium: Liquid

Small in size

With Printer

2GB SD card

Battery powered

Specifications

Transmitter
Power requirements Built-in 24V Ni-MH battery provides 24 hrs of continuous operation
Charging 220V AC 50/60 Hz
Velocity range 0-32m/s
Output RS485, heat
Display 2 line characters display instantaneous and accumulative flow, velocity and signal status
Units m3(/s/m/h/d), cubic feet, liter, gallon, etc.
Ambient conditions -20 °C to +75 °C, 0 to 85% relative humidity
Size 220*125*92mm, 800g
Accuracy Flow: ± 1% reading, Heat: ± 2%(at calibrated conditions)
Repeatability 0.20%
Transducer
Type S1 M1 L1
Applicable pipe (mm) 10~6000
Material PES (Polyether Sulfone)
Working frequency 1 MHZ
Installation method V, Z
Calibration Pairing & Calibrating for the complete machine
Magnetism no
Applicable temperature -40~160 °C
Protection IP68
Media type Water, seawater, sewage, alcohol, various oils and other single, uniform and stable liquid that can transmit ultrasonic wave
Medium turbidity 20000ppm with low bubble content
Applicable pipes Uniform and compact pipes made of carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastics, and lining is permitted.
Pipe lining material Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, bakelite, polytetrafluoroethylene etc.
Signal cable Standard configuration: 5mX2, and 10mX2 or 15mX2 are optional.

Heat Measurement

The portable ultrasonic flow meter with optional heat flow module installed is designed to measure the rate and quantity of heat delivered to a given building, area or heat exchanger. The meter measures the volumetric flow rate of the heat exchanger liquid (water, water/glycol mixture, brine, etc.), the high temperature at the inlet pipe and the low temperature at the outlet pipe. Heat delivery is calculated by the following equation.

Rate of heat delivery = Q*(Tin – Tout)*c
Where
Q = volumetric flow rate
Tin = high temperature at the inlet
Tout = low temperature at the outlet
C = specific heat of the liquid

Handheld Ultrasonic Flow meter

Use medium:Liquid

New design, new shape

Two Line LCD display

English, Italian and Chinese are available

Modbus/RS485 protocal

2GB storage card



Transmitter
Power requirements Built-in 24V Ni-MH battery provides 24 hrs of continuous operation
Charging 220V AC 50/60 Hz
Protocal RS485
Display 2 line characters display instantaneous and accumulative flow, velocity and signal status
Units m3(/s/m/h/d), cubic feet, liter, gallon, etc.
Ambient conditions -20 °C to +75 °C, 0 to 85% relative humidity
Size 220*120*92mm, 600g
Flow rate 0-32m/s
Accuracy 1~3%
Repeatability 0.20%
Transducer
Type S1 M1 L1
Applicable pipe (mm) 15~100; 50~700; 300~6000
Material Aluminum alloy
Working frequency 1 MHZ
Installation method V (N,W)
Calibration Pairing & Calibrating for the complete machine
Magnetism Yes
Applicable temperature -40~90 °C
Protection IP68
Media type Water, seawater, sewage, alcohol, various oils and other single, uniform and stable liquid that can transmit ultrasonic wave
Medium turbidity <20000ppm with low bubble content
Applicable pipes Uniform and compact pipes made of carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastics, and lining is permitted.
Pipe lining material Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, bakelite, polytetrafluoroethylene etc.
Signal cable Standard configuration: 5mX2, and 10mX2 or 15mX2 are optional.

Handheld Ultrasonic Flowmeter

Use medium:Liquid

Linearity: better than 0.5%

Repeatability: better than 0.2%

Accuracy: better than ±1%

Non-intrusive, clamp-on transducer

No pressure drop, no pipe disturbance



Items Performance and Parameter
Main Unit Principle transit-time ultrasonic flowmeter
Accuracy Accuracy :over 1%-2%; Repeatability: over 0.2%
Display 4 line x 16 character LCD with backlight
Dimension 200*93*33cm: 390g
Operation Support 16 key light touch keyboard and the Simulation keyboard software
Data interface Insulate RS232 serial interface, upgrade the flew meter software by computer, support the MODBUS, etc.
Signal Output 1 way OCT output
Special Cable Twisted-pair cable, ;Select the RS232 communication.; Generally, the standard is 5m*2, optional 10m*2
Pipe Condition Pipe Material Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed.
Pipe Diameter DN 15---6000mm
Straight length pipe Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump.
Measuring Medium Type of Liquid Water ; Ultra-pure liquids; Solvents and other liquids
Temperature Standard Transducer: -30--90℃; High-temperature transducer: -40--160℃
Turbidity under 10000ppm and less bubble
Flow rate 0--±10m/s
Flow Direction Measuring two (plus-minis) direction of flow rate
Working Environment Temperature Main Unit: -20--60℃
Flow transducer: -40--160℃; Temperature transducer: according to the customer’s demands.
Straight length pipe Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump.
Power Supply AC 110V-240V

Wall mounted clamp on Ultrasonic Flow Meter

Use medium:Liquid

Linearity: better than 0.5%

Repeatability: better than 0.2%

Accuracy: better than ±1%

Non-intrusive, clamp-on transducer

No pressure drop, no pipe disturbance



Items Specifications
Main unit 2 line x 20 character LCD with backlight
Working temperature: -25--60℃
Mini thermal printer with 24 line character output
4x4+2 pushbutton keypad
RS-485 interface for networking
Signal input & output 1 channel 4-20mA output
1channel OCT output
1channel relay output
3 channel 4-20mA input
Medium Water (hot water, chilled water, city water, sea water, waste water, etc.);
Sewage with small particle content;
Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, acids, etc.);
Plant effluent; Beverage,
liquid food; Ultra-pure liquids; Solvents and other liquids
Flow rate Range 0~±10m/s
Accuracy Better than ±1%
Battery Built-in rechargeable Ni-MH rechargeable battery, provide over 20 hours of continuous operation
Power Consumption 1.5W
Power supply Built-in rechargeable Ni-MH battery (for 20 hours operation) or AC 220V
Weight & Dimensions 2.5kg ; 225*180*67mm:
Remarks With a high strength carrying case suitable for normal and harsh environment